How many BTU does your home need?

Answer a few questions: your house builds itself on screen, then we calculate how much heat it loses in winter and gains in summer, using the CSA F280 method.

LIVING ROOMKITCHENZ-PRO 27,00012,0009,000
MontrealDesign -23 °C
Load covered at -23 °C : 100 %
Heating at -23 °C24,000BTU/h
Cooling at 30 °C14,600BTU/h

Estimate using the CSA F280-12 method (component-by-component heat loss), with typical values for your construction period. This is not a signed load calculation report.

Your Kanartic system

Number of zones (rooms with an indoor unit)
Pick my rooms one by one

Add each room where you want an indoor unit (8 maximum). Each floor’s load is shared among its rooms by floor area.

    DIY · recommendedfrom $4,725

    Z-PRO 27,000 BTU multi-zone · 2 zones

    Indoor units : 12,000 (Main floor) · 9,000 (Main floor)

    Pre-charged line sets and quick connectors: no refrigerant handling, no HVAC tools.

    Covers 100% of the heating load at -23 °C

    The heat pump carries the house on its own all winter.

    See on kanartic.ca

    Quebec: Kanartic commissioning

    A Kanartic technician starts up your DIY installation and gives you the invoice required for LogisVert.

    Estimated LogisVert rebate with commissioning: $3,240

    See commissioning

    Rebates in your province (Quebec)

    • LogisVert – Efficient heat pump · Hydro-Québec

      $50 per 1,000 BTU/h of heating at −8 °C (ENERGY STAR); $120 per 1,000 BTU/h for a cold-climate model. E.g. 12,000 BTU/h wall unit ≈ $1,440

      DIY eligible with Kanartic commissioning Official site

    • National Heat Pump Rebate (announced) · Gouvernement du Canada

      $2,000; up to $10,000 for low- and median-income households

      Criteria to be confirmed Official site

    Get my summary

    Your calculation, your system and your rebates by email, with a link back to your house.

    How we calculate

    1. Your city’s temperature

      We start from your city’s outdoor design temperature (National Building Code 2020, Appendix C): the temperature that is only undercut 2.5% of January hours. In Montreal it is −23 °C; in Edmonton, −32 °C.

    2. Every surface, one by one

      Walls, windows, roof, basement: for each component we multiply its area by its conductance (the inverse of its RSI value) and by the temperature difference. That is the CSA F280 component method.

    3. The air that leaks in

      A house also loses heat through air leaks. We estimate infiltration from the typical airtightness of your construction period (air changes at 50 Pa) or from your blower-door test.

    4. Summer too

      For cooling we add the sun entering each window by orientation, heat through the roof and walls, heat from people and appliances, and the moisture to remove.

    5. The right unit, not the biggest

      We pick the Kanartic system that covers your heating load at the design temperature without oversizing. An oversized heat pump short-cycles, dehumidifies poorly and wears out faster.

    Install it yourself (DIY)

    Kanartic DIY versions ship with pre-charged line sets and quick connectors. You mount the units, drill the wall, connect and plug in: no refrigerant handling.

    1. 1

      Mount the indoor unit

      On an exterior wall, high up, using the supplied template.

    2. 2

      Drill the passage

      A 2½–3 in. hole to the outside, sloping slightly down.

    3. 3

      Set the outdoor unit

      On a ground or wall bracket, above the snow line.

    4. 4

      Connect the line set

      Quick connectors thread on by hand, then with a wrench — no vacuum, no recharge.

    5. 5

      Wire the power

      A dedicated 240 V circuit; call an electrician if needed.

    Tools: drill, hole saw, level, torque wrenches. Plan one day for a first unit.

    In Quebec, Kanartic commissioning completes your DIY installation: a technician checks it, starts it up and gives you the invoice LogisVert requires.

    Frequently asked questions

    How many BTU per square foot?

    The rule of thumb (20 to 30 BTU per sq ft) is often off by a factor of two, because it ignores climate, insulation, windows and airtightness. A recent 1,800 sq ft house in Montreal often needs less than 30,000 BTU/h, while an older house of the same size can need twice that.

    Does a heat pump heat at −30 °C?

    Yes. Kanartic cold-climate models keep heating at −30 °C and do not shut off when it gets colder. The calculator tells you whether the heat pump is enough on its own at your city’s design temperature.

    Should I go bigger to be safe?

    No. An oversized unit keeps starting and stopping, uses more energy and controls humidity poorly in summer. A right-sized unit with your current heating as backup for the rare extreme days is better.

    Wall unit or multi-zone?

    A wall unit heats an open area or a single room well. As soon as the house has several floors or closed rooms, a multi-zone puts an indoor unit in each zone, connected to one outdoor unit.

    Can I install it myself?

    Yes, anywhere in Canada, with the DIY versions: pre-charged line sets and quick connectors, no refrigerant handling. Only the 240 V wiring may require an electrician depending on your province.