To heat 2,000 sq ft (186 m²) you need between 30,000 and 66,800 BTU/h depending on your city and insulation. Here is the calculation city by city, using the CSA F280 method.
Assumption: a 2,000 sq ft two-storey house with no heated basement, 8 ft ceilings, windows in proportion to floor area.
Heating load by city and house age
| City | After 2010 | 1990 to 2010 | 1970 to 1990 | Before 1970 | Cooling* |
|---|---|---|---|---|---|
| Vancouver (-7 °C) | 30,000 | 30,000 | 30,000 | 35,900 | 15,700 |
| Toronto (-18 °C) | 30,000 | 30,000 | 37,200 | 49,500 | 18,200 |
| Halifax (-16 °C) | 30,000 | 30,000 | 35,300 | 47,000 | 15,000 |
| Montreal (-23 °C) | 30,000 | 30,000 | 41,900 | 55,600 | 16,900 |
| Quebec City (-26 °C) | 30,000 | 30,900 | 44,600 | 59,400 | 15,700 |
| Winnipeg (-31 °C) | 30,300 | 34,100 | 49,300 | 65,500 | 16,900 |
| Edmonton (-32 °C) | 30,800 | 34,700 | 50,200 | 66,800 | 15,000 |
* Cooling for a 1990–2010 house, at the city’s summer design temperature.
Which Kanartic system for 2,000 sq ft?
Newer house in Toronto
Z-PRO 36,000 · 2 zonesfrom $5,325 · DIY
Covers 100% of the heating load at -18 °C
See on kanartic.ca1990–2010 house in Montreal
Z-PRO 36,000 · 2 zonesfrom $5,325 · DIY
Covers 100% of the heating load at -23 °C
See on kanartic.caPre-1970 house in Edmonton
Z-PRO 36,000 · 2 zones + ZERO 24,000 wall unitfrom $8,974 · DIY
Covers 90% of the heating load at -32 °C
See on kanartic.caWhat about 25 BTU per square foot?
The rule of thumb would give 50,000 BTU/h for 2,000 sq ft. The component calculation gives 30,000 to 66,800 BTU/h: depending on the house and climate, the rule is off by −25% to +67%.
Frequently asked questions
Is a 12,000 BTU heat pump enough for 2,000 sq ft?
In Montreal, for a 1990–2010 house, a 12,000 BTU unit covers 40% of the load at -23 °C; for a pre-1970 house, 22%. So you need a bigger unit or backup heat.
How many BTU to cool 2,000 sq ft?
Between 15,000 and 18,200 BTU/h for a 1990–2010 house, depending on the city. In Canada, heating sets heat pump size, not cooling.
Wall unit or multi-zone for 2,000 sq ft?
At this size, a multi-zone puts one indoor unit per floor or large room, connected to a single outdoor unit.